<?xml version="1.0" encoding="utf-16"?>
<xsd:element name="WaitProcess" type="xsd:duration">
<xsd:annotation>
<xsd:documentation>Machine waiting for other partners in the process or for process reasons not caused by the machine itself. This may be an (autonomous) machine waiting for access to a shared tramming zone or waiting for access to a dump shaft, a truck to become available etc. See "IREDES Drill Rig profile description" document.</xsd:documentation>
<xsd:documentation>START COUNTING: As soon as the working machine stops due to external process related reasons. Or as soon as the machine is for some other reason put back into working state and is unable to continue working due to such reasons</xsd:documentation>
<xsd:documentation>STOP COUNTING: As soon as the machine detects the external reasons for this mode are not valid any longer. Normally the machine then continues in the working mode. However, by operator input it may be put in any other state.</xsd:documentation>
</xsd:annotation>